Infant Baby (Newborn to 2/3 Year Baby)Infant Baby
Two parameters: SPO2, Pulse Rate
Four direction adjustable
Low voltage indicator
Automatically power off in 8 seconds when there is no signal
Small in volume, light in weight, and convenient to carry
Display Type: OLED display
Sp02:
Measurement range: 70%~99%
Accuracy: ±2% on the stage of 80-99%
Resolution: ±1%
Low Perfusion: <0.4%
PR:
Measurement range: 30BPM~240BPM Accuracy: ±1BPM or ±1% (the larger one)
Our jaundice meter is an accurate, non-invasive device that will assist you to test neonatal jaundice instantly since the detector is placed on the neonatal skin. This prevents the neonates from any discomfort typically associated with abstraction of blood samples, reduces costs since test results are immediate, and increases the working efficiency of doctors and nurses. It's the best choice in the clinical examination of neonatal jaundice. Our jaundice meter is developed with advanced electronics and optics, adopting Fiber Optics, spectrum splitter, controlled spectrum filter, NFM switching, and information processing techniques.
Features:
- LCD Display is easily viewable
- Streamlined design makes it small, delicate and easy to be handled.
- Long service life, low energy consumption.
- Battery indicator indicates when battery needs recharging.
- Test results are rapid providing serum bilirubin concentration.
- Storage and memory function.
- Convenient to browse and delete functions.
- Convenient self calibration.
- Easy use and maintenance.
Specifications:
- Display: LCD, 3 figures
- Power: AA 1.5V× 2 batteries
- Indicator light for ready: Green
- Measurement range: 0.0mg/dL ~30.0mg/dL;
- Measurement accuracy: Low+1.0mg/dL(+17μmol/L, rest ± 1.5mg/dL(± 25.5μmol/);
- Preparation time: <12 seconds - Record function: Memory 20 latest measuring results and circularly reviews recorded data.
- Reexamination rate: <10%
CMS5100 Patient Monitor is a feature-rich monitoring device that can be applied to adults, pediatric and neonate. User can choose different measurement parameters according to different needs. The patient monitor can monitor NIBP, SpO2 and PR. It integrates the function of parameter measuring and displaying into a compact, lightweight patient monitor, which is suitable for all levels of hospitals, community medical and home use.
Features
1)Be applicable for NIBP and SpO2 monitoring of adult, pediatric and neonate of all ages, easy to operate, high cost-effective;
2)Be applicable for medicine, surgery, operating room, ICU/CCU, emergency room, obstetrics and gynecology, pediatrics;
3)Compact and flexible appearance, easy for carrying and suitable for indoor and outdoor (in ambulance) monitoring;
4)Built-in rechargeable lithium polymer battery, ensuring uninterrupted monitoring;
5)Perfect menu design, user-friendly interface;
6)Display the measurement result of SYS, DIA, MAP, SpO2, PR and bar graph by the display screen of high-brightness digital tube;
7)2.8'' (320×240) true color TFT LCD screen, displays the information of time, SpO2 Plethysmogram, alarm condition, trend graph, list and system settings, etc.;
8)Visual and audible alarm for SYS, DIA, MAP, SpO2 and PR, and upper and lower limit of alarm can be set as necessary;
9)Independent nonvolatile memory, storage for up to 2,000 groups of NIBP data and 78,000 groups of SpO2 data;
10)Convenient and quick in reviewing measurement data, available for reviewing the NIBP trend graph of 24 hours and SpO2 trend graph of 22 hours.
Performance:
1 NIBP
Using Oscillometry technology, also called Oscillography technology to measure the blood pressure.
1)Measurement mode: manual/auto/continuous
2)Measurement interval in auto mode: 1, 2, 3, 4, 5, 5×n(n=2, 3, 4...51) min.
3)Resolution: 1 mmHg
4)Accuracy: max mean error: ±5 mmHg; max standard deviation: 8 mmHg.
5)Overpressure protection: dual protection for both software and hardware
6)Others: reset, self-testing and accuracy testing of static pressure
7)Measurement range:
Adult
SYS 40 mmHg~270 mmHg
MAP 20 mmHg~235 mmHg
DIA 10 mmHg~215 mmHg
Pediatric:
SYS 40 mmHg~200 mmHg
MAP 20 mmHg~165 mmHg
DIA 10 mmHg~150 mmHg
Neonate:
SYS 40 mmHg~135 mmHg
MAP 20 mmHg~110 mmHg
DIA 10 mmHg~100 mmHg
2 SpO2
Using Photoelectric Oxyhemoglobin Inspection Technology combined with Capacity Pulse Scanning & Recording Technology to measure the saturation of blood oxygen.
1)Measurement range: 0 %~100 %
2)Alarm range: 0 %~100 %
3)Resolution: 1 %
4)Accuracy: 70 %~100 %, ±2 %; below 70 % unspecified.
3 PR
Using Photoelectric Oxyhemoglobin Inspection Technology combined with Capacity Pulse Scanning & Recording Technology to measure the pulse rate.
1)Measurement range: 25 bpm~250 bpm
2)Alarm range: 25 bpm~250 bpm
3)Resolution: 1 bpm
4)Accuracy: ±2 bpm or ±2 %, whichever is greater
4 Safety and Power supply
1)Power supply: rated voltage: ~220 V, rated power: 50 Hz
2)Safety classification: Class I equipment, type BF defibrillation-proof applied part
Accessories:
1)User Manual 1pc (GB only)on request for other Language
2)Power cord 1pc
3)Power adapter 1pc
4)SpO2 sensor 1pc
5)Adult NIBP cuff 1pc
6)NIBP extension tube 1pc
CERTEZA Medical is a leading company in medical equipments for health monitoring and therapy. The range of products includes nebulizers, blood glucose monitors, blood pressure monitors, digital fever thermometers and many more. Committed to offer the best in healthcare equipments to help you build a healthy lifestyle.
Product Features:
Measurement of arterial oxygen saturation (SpO2)and heart rate (Pulse)
For use at home and on the go
For persons with: Heart failure, Chronic bronchitis, Asthma