Feature | Specification |
---|---|
ECG Leads | Simultaneous 10 Leads Resting ECG (12 channel) |
Dimension | 290 (W) x 300 (D) x 97.5 (H) mm |
Approximately 3.5 kg (Main Body) | |
Recording Channel | 3CH+1RHY, 3CH+3RHY, 6CH+1RHY, 12CH, 1CH Long Time (1min) and Beat Report |
Sensitivity | 2.5, 5, 10, 20, Auto (I~aVF: 10, V1~V6: 5) mm/mV |
Printing Speed | 5, 12.5, 25, 50, 100mm/sec |
Sampling Rate | Analysis Sampling Rate: 500 sample/sec Digital Sampling Rate: 8,000 sample/sec |
Filters | AC (50/60Hz, -20dB or better), Muscle (25~35Hz, -3dB or better), Base Line Drift (off, 0.05, 0.1, 0.2Hz, -3dB or better), Low Pass Filter (off, 40Hz, 100Hz, 150Hz) |
Display | 272 x 480 Pixel Resolution, 4.3” Color TFT Display 12 Channels Preview, ID, HR, Gain, Speed, Power Status |
Export file format | ECG, XML, PDF, JPEG, MFER |
User Interface | Touch Screen, Rotary Push-knob |
Recorder | Thermal Print Head, Roll Paper Report Paper - Width: A4/Letter – 215mm (8.5”) - Length: A4 – 297mm (11.7”) Letter – 279mm (11”) Resolution: 8dot/mm (0.125mm pitch) |
Patient data | ID, Name, Age, Gender, Height, Weight |
Basic Measurement | Heart Rate: 30~300bpm (±3bpm) PR, QRS, QT/QTc, P-R-T axis |
ECG Data Storage | Internal Storage for 200 ECGs: Built- in Memory External memory available |
Electrical | Internal Noise: 20uV(p-p)max |
Input Impedance: More than 50MΩ | |
Input Voltage range: ±5mV | |
CMRR: Greater than 105dB | |
DC offset Voltage: ≥ ±400mV | |
Patient Leakage Current: < 10uA | |
Frequency Response: 0.05~150 with in –3dB | |
Isolated, Defibrillation and ESU Protected | |
Signal Quality Control | Pacemaker Pulse Detection Lead Fault Detection, Signal Saturation Detection |
Power | Input: 100-240Vac, 1.5-0.75A, 50-60Hz, Output: 15Vdc, 4.2A |
Battery type | Replaceable and Rechargeable, Lithium ion, 11.1V, 2600mA |
Battery Capacity | 6 hours of normal use (without recording,200 ECGs) with 12 channel Battery charge time is 3 hours. |
Communication | LAN, USB, WIFI (option) |
Safety Conformity | Class I, Type CF Defibrillation-proof applied Part |
Environment | Operating Temperature: 5~40°C Operating Humidity: 10~90%RH Atmospheric Pressure: 70~106KPa |
Standard Accessory | Power Cord - 1 ea Patient Cable - 1 ea ECG clips - 1 set Disposable Electrodes - 1 pouch Chart paper - 1 ea Operation manual - 1 ea Rechargeable battery - 1 ea |
Options | Cart, Hanger, USB WiFi dongle |
1. Optical Specification |
|
– Diameter of the light spot at a distance of 420mm: | 20-80mm |
– Illumination at 200mm working distance: | >50000 Lx |
2. Adjustable Range |
|
– Fluctuation distance: | 12. 5mm |
– Direction of Illumination: | Vertical ±25°adjustable |
3. Weight |
|
– Head lamp: | 69g |
4. Electrical specifications |
|
– Illumination Source: | Extremely bright light, 5W LED, life 20.000 hours continuous burn |
– Battery: | 7. 4V Lithium battery 1800mAh |
– Battery Run-time: | > 3 hours |
– Input voltage: | 100-240VAC |
– Maximum Power input: | 24VA |
– Electrical Safety standard: | IEC60601. 1, class II equipment |
Brand |
|
Type |
|
Model ID |
|
Color |
|
Height (cm) |
|
Width (cm) |
|
Depth (cm) |
|
Weight (gram) |
|
Operating Air Flow Rate |
|
M mad (micro m) |
|
Medication Capacity (ml) |
|
Average Nebulization Rate (ml/min) |
|
Particle Size (micro m) |
|
Power Source |
|
Power Consumption |
|
Here We Are!